Dry Contact Sensors & Detectors
(for use with 10 Port Dry Contact RIMS and HEAT RIMS)Monitor for smoke, gas levels, water, and unauthorized human access with our line of dry contact sensors and detectors. It is often impractical to have staff physically check conditions of a server room or data center, which increases the importance of having an automated monitoring system. Use with the 10 Port Dry Contact RIMS and HEAT RIMS.
|
- Measurement Range: Alarm / Normal
- Measurement Rate: One reading each second
- Communications Cable: Cat5 Cable
- Sensor Type: Reed dry contact
- Sensor Disconnection Detection: Yes
- Sensor Power: No additional power needed
- Trap Information: Alarm- Sensor Number, Sensor Description, Error/ Normal
|
- Sensor Lengths Available: 15 ft and 60 ft
- Measurement Range: Wet or Dry ( -20°C +60°C)
- Measurement Rate: One reading each second
- Measurement Accuracy: Able to measure distilled water
- Communications Cable: Cat5 Cable
- Sensor Type: Patent pending, microprocessor controlled, capacitance measurement technology
- Sensor Disconnection Alarm: Yes
- Sensor Power: No additional power needed
- Trap Information: Alarm-Sensor Number, Sensor Description, Wet or Dry
|
- Measurement Range: Alarm / Normal
- Measurement Rate: One reading each second
- Communications Cable: Cat5 Cable
- Sensor Power: No additional power needed
- Input: The input pin can then sense whether a switch is open or closed by the completion or interruption of the circuit
|
- Fireproof ABS housing
- LED ON/OFF optional
- Automatic temperature compensation
- SMT adopted, anti – RFI & anti – EMI
- Pulse count optional
- Alarm output N.C./N.O. optional
|
- Ceiling mounted
- Fireproof ABS housing
- LED OM/OFF optional
- Automatic temperature compensation
- SMT adopted, anti – RFI & anti- EMI
- Pulse count optional
- Alarm output N.C./N.O. optional
|
- ASIC control
- Manual test, auto-reset
- Infrared photoelectric sensor
- Network output/ LED indicator
- Thin structure design
- Strong adaptability to circumstance
- SMT adopted
- Dustproof, mothproof and anti- white light
- Low power indication
|
- High reliability sensor
- Auto – reset after alarm
- MCU processing adopted
- Malfunction auto-check indicator
- Alarm output N.C./N.O. optional
- Dual sensor design
- Be able to work with electrovalve/exhaust fan
- SMT adopted, excellent stability
- Available for natural gas, LPG,CO
|
- Auto reset after alarm
- MCU process
- Sensor with high stability and low power consumption
- Auto check and indication for multifunction
- Detecting natural gas and LPG SMT adopted
- Electrovalve optional
- Support exhaust fan
|
- Auto reset after alarm
- MCU process
- Sensor with high stability and low power consumption
- Auto check and indication for malfunction
- Detecting carbon monoxide
- Electrovalve optional
- Support exhaust fan
|
|
|
- Customer's who ordered this product also ordered
|