Critical Power
Server Racks | Enclosures
Rackmount Accessories
Non-Rackmount Products
Miscellaneous

LP-11 Series - UPS

Designed with high efficiency mode up to 97% and provides galvanic isolation to the load. For use with medium data networks, telecom, and local site protection. (120 - 240V). Call 1-800-352-3361 for assistance in selecting your UPS.


General Electric Logo

General Electric LP11 Series

Related Market:
Data Center, Telecom


LP 11 Series UPS - CE Listed (3 - 10kVA)

General Electric's LP11 Series is a true VFI on line, double conversion transformer-based UPS with the most advanced power technology. Designed to provide the highest level of protection for all critical loads from all utility variances and failure the LP11 Series UPS is one of the most sought after in the industry.

The LP11 is easy to install and service and can be integrated into your standard office environment or far more hardened commercial and industrial environments. RPA (Redundant Parallel Architecture) technology provides a scalable system and allows users to parallel up to 4 UPS as load demands require. RPA also allows for redundant UPS to be installed, increasing total system reliability and eliminating single points of failure.

LP11 communication includes RS232 and relays as standard while SNMP is available as an option. Extended runtime is available with the addition of matching battery cabinets. The LP11 Series also comes with a comprehensive two-year product warranty.

LP 11 Series UPS (3 - 10kVA) Features and Benefits:

  • Compact footprint and low noise - Easy to maneuver and install; suitable for installation even next to the user
  • Isolation transformer design - Ensuring no DC on the output; ultimate site safety
  • Matching battery cabinets - Extended runtime for all models
  • Compliance to all safety and EMI standards - CE certified
  • High reliability - >220,000 hours MTBF

LP 11 Series UPS (3 - 10kVA) Specifications:

  • Single Phase Output Voltages - 220/230/240V
  • Wide input voltage window - Minimizes battery use, prolongs battery life
  • RPA functionality for paralleling and redundancy - UPS capacity can be increased as site requirements require at no extra cost
  • Internal automatic bypass switch - Continuous power supply to the load even if the UPS is overloaded
  • 0.8 output power factor - Prevents the need to oversize the UPS
  • Manual automatic bypass switch - Integrated as standard to the rear of the UPS
  • GE's unique Superior Battery Management - Ultimate protection for the UPS core component
  • High efficiency 91% - 94% (model dependent) - Using ECO mode, high efficiency and low losses
  • No load shutdown - Prevents deep battery discharge al low loads
  • Frequency conversion 50/60Hz - Operates as a frequency converter also operating in a parallel system


General Electric Logo

General Electric LP11 5-10 kva Series

Related Market:
Data Center, Telecom

Download Critical Power Brochure Product Brochure


LP 11 Series UPS - UL Listed (5 - 10kVA)

GE's LP11 Series is a true voltage and frequency independent on line, double conversion transformer-based UPS. This unit is built with some of the most advanced power electronics technology on the market and engineered to provide an elite level of protection for all critical loads from all utility variances and failure.

An integrated transformer ensures galvanic isolation on the output for ultimate safe installation. Quick and easy to install and service, the LP11 Series can be integrated into office environments as well as more hardened commercial and industrial environments. General Electric's unique redundant parallel architecture creates a scalable system, allowing the user to parallel up to 4 UPS as load demands require. RPA also allows for redundant UPS to be installed, which increases the total system reliability and eliminates single points of failure.

RS232 and relays are standard communication on the LP 11 while SNMP is available as an option. An LCD screen provides clear status notifications for the UPS and the load, functions as a service screen to adjust UPS parameters and includes an event log as a resource.

LP 11 Series UPS (5-10kVA) Features and Benefits:

  • Compact footprint and low noise - Easy to maneuver and install; suitable for installation even next to the user
  • Isolation transformer design - Ensuring no DC on the output; ultimate site safety
  • Matching battery cabinets - Extended runtime for all models
  • Compliance to all safety and EMI standards - UL certified
  • High reliability - >220,000 hours MTBF
  • PDU options - Options to suit several output configurations

LP 11 Series UPS (5-10kVA) Specifications:

  • UL 1778 listed
  • IEC 61000-4-5 surge protection
  • IEC 60529 & Din 40050 environment protection
  • FCC part 15, class A

LP 11 Series UPS (5-10kVA) Product Scope:

  • Single Phase Output Voltages - 120/208/230/240V
  • Wide input voltage window - Minimizes battery use, prolongs battery life
  • RPA functionality for paralleling and redundancy - UPS capacity can be increased as site requirements require at no extra cost
  • Internal automatic bypass switch - Continuous power supply to the load even if the UPS is overloaded
  • 0.8 output power factor - Prevents the need to oversize the UPS
  • 0.99 input power factor
  • Manual automatic bypass switch - Integrated as standard to the rear of the UPS
  • GE's unique Superior Battery Management - Ultimate protection for the UPS core component
  • High efficiency 91% - 94% (model dependent) - Using ECO mode, high efficiency and low losses
  • No load shutdown - Prevents deep battery discharge al low loads
  • Frequency conversion 50/60Hz - Operates as a frequency converter also operating in a parallel system


General Electric Logo

General Electric LP11 6-10kva Series

Related Market:
Data Center, Telecom

Download Critical Power Brochure Product Brochure


LP 11 Series UPS - UL924 Listed (6 & 10kVA)

GE's LP11 924 Series is a true VFI on line, double conversion transformer-based UPS engineered to provide protection for all critical loads from all utility variances and failure.

The LP11 924 Series product line includes both the UPS system and all required line and match battery cabinets required to achieve the minimum 90 minutes of run-time. This completely tested UPS and 90-minute minimum battery system carries a UL 924 listing. GE's unique RPA provides a scalable system, allowing the user to parallel two UPS as load demands require. RPA also allows for redundant UPS to be installed, increasing reliability and eliminating single points of failure.

Communication options includes RS232 and relays as a standard while SNMP is available as an option. The UPS incorporates a small footprint while providing high power and runtime capacity, making it a great choice as a cost-effective solution.

LP 11 Series UPS (6 & 10kVA) Features and Benefits:

  • Compact footprint and matching battery cabinets
  • Isolation output transformer design - Ensuring no DC on the output; ultimate site safety
  • Matching battery cabinets ? Sized for UL924 minimum 90-minute runtime
  • Up to 90% operating efficiency in double-conversion mode
  • High efficiency 90% - 96% (model dependent) - Using ECO mode, high efficiency and low losses
  • Wide input voltage window - Minimizes battery use, prolongs battery life
  • No load shutdown - Prevents deep battery discharge al low loads
  • RPA functionality for paralleling and redundancy - UPS capacity can be increased as site requirements require at no extra cost

LP 11 Series UPS (6 & 10kVA) Scope:

  • 6 & 10kVA
  • Single Phase Input Voltages - 120/208/240/277Vac
  • 0.8 output Power Factor
  • UL924 Listed for Emergency Lighting and Power Equipment
  • Single Phase Output Voltages - 120/208/230/240, 277V
  • 50/60Hz
  • FCC part 15, Class A
  • > 0.99 input Power Factor
  • 150-minutes Standard backup time at 100%load and 0.8PF (6kVA UPS)
  • 93-minutes Standard backup time at 100%load and 0.8PF (10kVA UPS)

For help selecting the right UPS for your space
contact power@rackmountsolutions.net or call (800) 352-6631